SKU: 77839744050

Mouse IFN-γ Kit (HICA)

Sale price$719.55 Regular price$799.50
Save 10%

Pay in installments of $199.88 with ShopPay, AfterPay and Klarna

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 17 - Jul 22

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Mouse IFN-γ Kit (HICA)Product Specification Stability & Storage Store at 2~8C protected from light for 12 months; after reconstitution, the standard can be aliquoted and stored at 20C, avoiding repeated freeze thaw cycles. Background Principle of the Assay: This kit employs a homogeneous immuno chemiluminescence assay (HICA) based on the double antibody sandwich method for the detection of cytokine concentrations. The operation is simple and requires no washing steps. The

Product Specification


Stability & Storage

Store at 2~8°C protected from light for 12 months; after reconstitution, the standard can be aliquoted and stored at -20°C, avoiding repeated freeze-thaw cycles.

Background

Principle of the Assay:

This kit employs a homogeneous immuno chemiluminescence assay (HICA) based on the double-antibody sandwich method for the detection of cytokine concentrations. The operation is simple and requires no washing steps.

The detection system consists of two types of microspheres: receptor microspheres conjugated with antibody 1 targeting the protein of interest, and donor microspheres conjugated with streptavidin, along with biotin-labeled antibody 2. During the reaction, the target protein binds with the antibodies and microspheres to form an immune complex, bringing the two types of microspheres into close proximity. When the distance between the donor and receptor microspheres is less than 200 nm, singlet oxygen generated by light excitation can transfer to the receptor microspheres and trigger chemiluminescence. Conversely, if the target protein is absent, the distance between the microspheres is too large, and no signal is produced.

By measuring the intensity of the chemiluminescent signal, the target protein can be quantitatively analyzed. This method offers advantages such as simplicity, rapid reaction, and high sensitivity.

Components

Name

Specification

Component Specification

Detection ReagentR1

500T

2mL/Vial×1

2000T

8ml/Vial×1

10000T

40ml/Vial×1

Detection ReagentR2

500T

2mL/Vial×1

2000T

8ml/Vial×1

10000T

40ml/Vial×1

Detection ReagentR3

500T

5mL/Vial×1

2000T

20ml/Vial×1

10000T

100ml/Vial×1

Standard

500T

0.05μgLyophilized Powder×1

2000T

0.05μgLyophilized Powder×2

10000T

0.05μgLyophilized Powder×5

StandardBuffer

500T

6mL/Vial×1

2000T

12ml/Vial×1

10000T

30ml/Vial×1


Note: Microtiter plates (384- or 96-well plates, white, shallow wells)

Protocol

I. Sample Requirements
1. To remove impurities from samples, samples need to be centrifuged before detection (1000 ×g, 10 minutes).
2. When detecting target proteins in serum samples, standards should be diluted using negative serum with background values below the detection limit, and a standard curve should be established accordingly to calculate the actual concentration.
3. If the measured concentration of a sample exceeds the highest value of the standard curve, it needs to be appropriately diluted and re-tested to ensure the result falls within the valid measurement range.

II. Detection Procedure 

2.1 Preparation of Standard Gradient Samples Reconstitute the lyophilized standard with 50μL deionized water, then dilute the standard using standard buffer. The recommended dilution scheme is shown in the table below:

Gradient

Concentration (pg/mL)

Standard (μL)

Diluent (μL)

C12

100000

20μL calibrator

180

C11

30000

60μL C12

140

C10

10000

60μL C11

120

C9

3000

60μL C10

140

C8

1000

60μL C9

120

C7

300

60μL C8

140

C6

100

60μL C7

120

C5

30

60μL C6

140

C4

10

60μL C5

120

C3

3

60μL C4

140

C2

1

60μL C3

120

C1

0

120


 

 

2.2 Detection Procedure:

Detection Procedure

Detection Procedure 1 (37℃ Rapid Detection)

Detection Procedure 2 (Room Temperature Detection)

Step 1:

Take 2µL sample, add 8µL pre-mixed R1+R2*

Take 2µL sample, add 8µL pre-mixed R1+R2*

Incubation

​Mix by shaking at 400r/min for 1min, incubate at 37℃ for 15 minutes

​Mix by shaking at 400r/min for 1min, incubate at room temperature for 60 minutes

Step 2:

Add 10µL R3,protect from light/green light

Add 10µL R3,protect from light/green light

Incubation

​Mix by shaking at 400r/min for 1min, incubate at 37℃ for 10 minutes,protect from light/green light

​Mix by shaking at 400r/min for 1min, incubate at room temperature for 30 minutes,protect from light/green light

Reading

Instrument reading,protect from light/green light

Instrument reading,protect from light/green light


 

* Note: Before testing, pre-mix R1 and R2 at a volume ratio of 1:1, and use within 1 hour after mixing.


III. Performance Testing

3.1 Example of Complete Standard Curve:

 

 

 


3.2 Performance Parameter Verification:

LOD: Repeat detection of standard C1 for 20 times, calculate the mean signal and SD, and use the standard curve to calculate the concentration value corresponding to mean signal + 2×SD, which is the Limit of Detection (LOD).

Detection Procedure

Matrix

LOD (pg/mL)

Quantification Range (pg/mL)

Dynamic Range (pg/mL)

Detection Procedure 1

Buffer

0.71

0.7~10000

0~100000

DMEM

2.28

2.3~10000

RPMI

5.84

5.8~10000

Mouse Serum

5.22

5.2~10000

Detection Procedure 2

Buffer

8.63

8.6~10000


 


Precision
Intra-Precision: On the same experimental plate, known low, medium, and high concentration samples are each tested in 10 replicates to evaluate the intra-plate precision of the assay. Standards and samples are detected using different procedures. The coefficient of variation (%CV) of detection results for samples at each concentration is below 10%, indicating good reproducibility of this method within the same batch detection.

Detection Procedure

Matrix

Repeatability

Low Concentration

High Concentration

Detection Procedure 1

Buffer

3.1%

3.0%

DMEM

3.8%

3.6%

RPMI

3.4%

1.5%

Mouse Serum

2.6%

2.8%

Detection Procedure 2

Buffer

7.7%

3.3%


 


Inter-Precision: Known low, medium, and high concentration samples are tested in 5 independent experiments. Standards and samples are all detected using Detection Procedure 1 with 5 replicates set. The detection results of samples at each concentration show low coefficients of variation (%CV < 10%), indicating good reproducibility of this method across different batch detections.

Detection Procedure

Matrix

Inter-Plate Precision

Low Concentration

High Concentration

Detection Procedure 1

Buffer

6.0%

5.6%


 

Accuracy (Recovery):

High and low concentration quality control samples are mixed at a ratio of 1:9 and tested for recovery rate, all within 80%-120%, indicating that this method has good accuracy.

Detection Procedure

Matrix

Recovery Rate

Detection Procedure 1

Buffer

92.4%

DMEM

109.7%

RPMI

86.4%

Mouse Serum

110.4%

Detection Procedure 2

Buffer

89.2%


 

Specificity: The following proteins are diluted to 0.3μg/mL using standard buffer, and cross-interference rates are tested.

Detection Procedure

Analyte

Cross-reactivity Rate

Detection Procedure 1

Human IFN-γ

0.00%

Human TNF-α

0.00%

mouse TNF-α

0.00%


 

Guidelines

Reagent R3 should be protected from light during use. It is recommended to perform sample addition and incubation under green light (<100 LUX). Each test requires recalibration, with at least duplicate wells for each standard concentration point. Use a four-parameter (weighting: 1/Y²) fitting method for calculation. During incubation, temperature and time must be controlled. It is advisable to cover the microplate with a film, and an ELISA reader with ALPHA function should be selected. The dilution matrix of the calibrator should match that of the test samples. The reconstituted calibrator should be used within 2 hours. Components from different reagent kit batches must not be mixed.

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 77839744050

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.8 ★★★★★
Based on 17 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
L
Verified Purchase
Love the dress
San Leandro, US
★★★★★ 5
Awesome quality for the price
Color: Black, Size: 8
Ordered size 8 for my son first communion great fit for the price was excellent
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 4, 2026
T
This Is My Review Name
Boise, US
★★★★★ 5
Perfect fit and great quality for the price
This suit was perfect for my son. The fit was exactly as expected. The quality is excellent for the price—it feels well made and durable enough to last through multiple wears. It doesn’t feel cheap or flimsy at all. It also looks really good on him. Clean, polished, and great for formal events like weddings or parties. Overall, a fantastic value with great quality and a great fit.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 9, 2026
N
Verified Purchase
Nicole S.
Bozeman, US
★★★★★ 3
Missing items
Color: Sky Blue, Size: 16
Was missing the tie that is supposed to come with it and it looked like it was tried on and thrown back in the bag. The sleeve to the jacket were rolled up.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on December 7, 2025
A
Alley Cat on a Homestead
New York, US
★★★★★ 5
Excellent Quality, Great Value, Great Look. Highly Recommend
Very well-made, there are some minor imperfections in the cuff sewing that aren't really noticeable when on. Liner is quality, color is spot on, and it fits true to size. If you're in the market for a toddler blazer and pants, you can't go wrong with this one in terms of quality, price, and the cut is perfect for a very polished look. There were a few loose strings to be clipped, but everything was correctly sewn and well. None of them affected the seam strength. The pants have a button and elastic on the waistband to make adjusting the waist size easier.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 14, 2025
A
Amazon Customer
Phoenix, US
★★★★★ 5
Great boys slim fit suit for weddings, church, or special events
Color: Medium Grey, Size: 12
Great kids suit. Comes with a jacket, pants, and tie. Does not have a shirt. Fits as expected. Classic cut on the lapels. Great quality materials. Well made pants and jacket. The color is consistent without any fade or dark spots that can happen with lower quality fabrics. Looks great on. My son loves it. Says it is not restrictive, he can move easily in it. Highly recommend for church, special events, weddings, etc.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 22, 2025

recommand products